HURTIG LEVERING

LEVERING 1-3 DAGE.

ALTID NYE pRODUKTER !

Vi leverer altid enheder med den sidste nye Firmware/Software.

Altid nyeste varer på lager.

BRUG FOR HJÆLP ?

Mads Lund  Tlf. +4520275925

Poul Sørensen Tlf. +4523432758

[email protected]

Youcontrol.dk
Besøgende online :51
Presence recognition in Fibaro Home Center via Mother Sense Cookie
How to make FIBARO Home Center 2 Gateway
Fibaro RGBW in a pendent light or the Wofi LED Ring for modern living
Using Z-Weather in the Fibaro HomeCenter 2
FIBARO: Heating off when window open – How to save real cash
Easy LUA scripts part 3: How to change the FIBARO Wallplug´s color
netatmo welcome – read the presence-status with the Fibaro HomeCenter 2
This is how you set up the Fibaro Video-Gate as Door intercom #Tutorial
Fibaro Shortcuts: This is how your underfloor heating is going to be smart as well!
This is how you set up a heating schedule in the Fibaro Home Center
To check the Fibaro Presence via iPhone, Smartphone or TV
Sådan at aktivere din alarm med RFID-tag-læser
How to customize your FIBARO app?
FIBARO mobile app How to install the widgets
Fibaro & HomeKit - SmartHome stemmestyring med Siri nemt!
Sådan sender du SMS med Fibaro Home Center
IFFTT Fibaro
Filling the Weather Display of the HomeCenter 2 with your own Values
Using Z-Weather in the Zipabox
https://www.siio.de/sicherheitalarm/netatmo-welcome-kamerabild-im-fibaro-hc-anzeigen/
atom homey
Siio
Facebook
Powered by Magento extensions
YouTube
Powered by Magento extensions

FIBARO RGBW Controller 2

Vær den første til at bedømme dette produkt

Lagerstatus: På lager/fjernlager = 100 vare(r)

Pris: 449,00 DKK

Specialpris Ekskl. moms: 297,60 DKK Inkl. moms: 372,00 DKK

Hurtigt overblik

FIBARO RGBW Controller 2 - FIBEFGRGBW-442

FIBARO RGBW Controller 2

Flere visninger

 

Virker Med :


  • Home Center Lite ( JA ) 
  • Home Center 2 ( JA ) 
  • HomeSeer ( ? )
  • HOMEY ( ? ) Se mere HER
  • NEXA ( ? )
  • Razberry ( JA )
  • Vera ( ? )
  • Zipabox ( ? )
  • ZNet Lite V1/V2 ( ? )
  • HG2 ( ? )
  • Samsung SmartThings ( ? )

 

 

Hent Fibaros installations manual ENG klik her.

Hent Manual 2 ENG klik here.

 

 

 


Beskrivelse og funktioner

 

FIBARO RGBW Controller er en universel, Z-Wave kompatible RGB / RGBW controller. FIBARO RGBW Controller anvender PWM udgangssignal, som gør det muligt at styre LED, RGB, RGBW strimler, halogenlys og fans.Kontrollerede enheder kan være drevet af 12 eller 24 VDC. Derudover enheden understøtter op til fire, 0V - 10V analoge sensorer, såsom temperaturfølere, fugt sensorer, vind sensorer, luftkvalitet sensorer, lys sensorer etc. Alle IN og OUT-terminaler kan brugeren konfigureret til LED kontrol eller 0V-10V signal udlæsninger.

 

Funktioner:

  •     Radiomodul til installation af vægbokse
  •     Skift, dæmp og RGBW-valg af farvevalg
  •     Energimålefunktion
  •     Spænding: 12 V eller 24 V DC
  •     Maks. Output: 6 En enkelt kanal, 12 A alle outputkanaler i alt
  •     Energiforbrug: <0,3 W
  •     Op til 4 analoge (0-10 V) sensorer, der kan tilsluttes (sensorer er ikke inkluderet i leveringen)
  •     Trådløs teknologi: Z-Wave Plus
  •     Sikkerhed: S2
  •     SmartStart aktiveret
  •     Dimension: 42 x 38 x 18 mm

Denne enhed kan bruges med alle enheder, der er certificeret med Z-Wave certifikat og bør være forenelige med sådanne anordninger fremstillet af andre producenter.

 

 Understøttede belastninger

FIBARO RGBW Controller kan kontrollere:

  • 12 / 24VDC drevne RGB strips
  • 12 / 24VDC drevne RGBW strimler
  • 12 / 24VDC drevne LED strips, pærer osv
  • 12 / 24VDC drevne halogenlamper
  • 12 / 24VDC drevne lavt output power fans

 

Yderligere funktioner:

  • 0-10V sensorer signal udlæsninger
  • 0-10V potentiometer signal udlæsninger, og styring udgange i overensstemmelse hermed
  • kontrolleret af momentan eller vippekontakter

 

 Teknisk data

Strømforsyning: 12 / 24V DC
Nominel udgangseffekt: kombineret 12A (summen af alle tilsluttede output kanaler) 
6A for enkelt output kanal
PWM udgangsfrekvens: 244Hz
Elforbrug: 0,3 W
Radio signal magt: 1 mW
Til installation i kasser: Ø≥50 mm
Max belastning: på 12V - 144W kombineret 
på 24V - 288W kombineret
EU-direktiv overholdes: RoHS 2011/65 / EU 
EMC 2004/108 / EF 
R & TTE 1999/5 / EF
Radio-protokol: Z-Wave
Radiofrekvens: 868,4 MHz EU 
908,4 MHz US 
921,4 MHz ANZ 
869,0 MHz RUC
Rækkevidde: op til 50 m udendørs / op til 30m indendørs 
(afhængigt af terræn og bygningsstruktur)
Operationel temperatur: 0 - 40 ° C
Mål (L x B x H): 42.5 x 38.25 x 20.3 mm

 

 

Installation

 Grundlæggende aktivering

  1. Før installationen afbryde spændingsforsyningen.
  2. Slut FIBARO RGBW Controller ifølge et af de ledningsdiagrammer (første, tilslut udgange og / eller input, og tilslut spænding).
  3. Arranger antennen.
  4. Drej spænding på.
  5. Føj enheden til Z-Wave-netværk.

 

Advarsler:

  • FIBARO RGBW Controller er dedikeret til at operere i lavspændings kredsløb af 12VDC eller 24VDC.Tilslutning højere spænding belastning kan resultere i FIBARO RGBW Controller skader.
  • FIBARO RGBW Controller skal være drevet af den samme spænding som den tilsluttede lyskilde. Dvs. hvis styre 12V LED strip, skal modulet sluttes til 12 V strømforsyning. Tilsvarende, hvis styre 24V RGBW strimler, FIBARO RGBW Controller skal være drevet af 24V spændingsforsyning.
  • FIBARO RGBW Controller har 0-10V input. Der er ingen 0-10V output. Output styres af PWM på 244Hz.
  • FIBARO RGBW Controller skal være drevet af 12VDC eller 24 VDC stabiliseret strømforsyning med udgange lastkapacitet tilpasset belastninger spænding.
  • Sensorer med 0-10V-interface brug ledningsforbindelse til indgange I1 - I4. Maksimal længde af 0-10V tilslutning linje er 10 m. Overhold sensorens producentens anbefalinger til 0-10V line diameter.
  • I tilfælde af at forbinde lange RGBW / RGB / LED strips spænding kan forekomme dråber, hvilket resulterer i lavere lys lysstyrke længere fra R / G / B / W udgange. For at eliminere denne effekt det anbefales at forbinde nogle kortere strimler i parallelforbindelse i stedet for én lang strimmel tilsluttet serielt.
  • Maksimalt anbefalet wire længde, der anvendes til at forbinde R / G / B / W udgange med en RGBW / RGB / LED strip er 10 m. Overhold tilsluttede belastninger producentens anbefalinger i retning forbindelse tråddiameter.

     

 

Video tutorial

Video-afspiller

 
 
 

Description and features

 Description

FIBARO RGBW Controller 2 is a universal, Z-Wave Plus compatible RGB/RGBW controller.

FIBARO RGBW Controller 2 uses PWM output signal, allowing it to control LED, RGB, RGBW strips, halogen lights and other resistive loads. It can also measure active power and energy consumed by the load. Controlled devices may be powered by 12 or 24V DC.

Inputs support momentary/toggle switches and 0-10V analog sensors, like temperature sensors, humidity sensors, light sensors etc.

 

 Features

  • Compatible with any certified Z-Wave or Z-Wave Plus controller.
  • Allows for controlling:
    • RGB/RGBW LED strip,
    • one-color LED strips,
    • halogen lights,
    • other compliant resistive loads.
  • Allows for connecting to inputs:
    • switches/buttons,
    • 0-10V analog sensors or potentiometers.
  • Active power and energy metering.
  • Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption.
  • Works as a Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network).
  • May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.

The device is a Security Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be used in order to fully utilize the product.

 

 

 Specifications

Power supply: 12/24V DC ±10%
Rated load current: 6A for channel,
12A total for all outputs
Power output: 144W combined for 12V
288W combined for 24V
Inputs: 4 inputs, 0-10V (configurable pull-up) or binary
Outputs: 4 outputs, PWM
PWM frequency: 244Hz
Maximum length of wires: 2m
Operating temperature: 0–40°C (32–104°F)
Storage temperature: -40–60°C (-40–140°F)
Radio protocol: Z-Wave (500 series chip)
Radio frequency: 868.4 / 869.85 MHz EU;
908.4 / 916 MHz US;
919.8 / 921.4 MHz ANZ;
869.0 MHz RU;
Transmit power: EIRP max. +2dBm
Range: up to 50m (164 ft) outdoors
up to 40m (131 ft) indoors
(depending on terrain and building structure)
Recommended wire cross-section area 0.2–2.0mm2 (24–14 AWG)
(depending on load current)
Dimensions (Length x Width x Height): 42.35 x 36.90 x 17.5 mm
(1.67” x 1.5” x 0.69”)
Compliance with EU directives RoHS 2011/65/EU
RED 2014/53/EU

 

Radio frequency of individual device must be same as your Z-Wave controller. Check information on the box or consult your dealer if you are not sure.

The maximum load for one channel is 6A. Do not exceed this value as it can permanently damage the device.

 

 Important safety information

Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.

Do not modify!
Do not modify this device in any way not included in this manual. It might result in loosing warranty privileges otherwise.

 

Other devices
The manufacturer, Fibar Group S.A. will not be held responsible for any damage or loss of warranty privileges for other connected devices if the connection is not compliant with their manuals.


Danger of electrocution!

The device is powered with a secure voltage. Nevertheless, the user should be careful or should commission the installation to a qualified person.

To avoid risk of electrical shock, do not operate the device with wet or moist hands.

 

This product is intended for indoor use only in dry locations.
Do not use in damp or wet locations, near a bathtub, sink, shower, swimming pool, or anywhere else where water or moisture are present.

Not a toy!
This product is not a toy. Keep away from children and animals!

 

Installation

 Before installation

Connecting the device in a manner inconsistent with this manual may cause risk to health, life or material damage.

Connect only in accordance with one of the diagrams,
The device is powered with secure voltage; nevertheless, the user should be extra careful or should commission the installation to a qualified person,
Do not connect devices which are not compliant with the specification,
Every connected device should be compliant with the relevant safety standards,
RGBW Controller 2 and the load connected to its output must be powered by 12VDC or 24VDC stabilized power supply with short circuit protection. Connecting higher voltage or voltage not matching the load’s voltage may cause damage to the device,
Connecting long RGBW/RGB/LED strips may cause voltage drops, resulting in lower light brightness further from R/G/B/W outputs. To eliminate this effect it is recommended to connect few shorter strips
in parallel connection instead of one long strip connected serially,
RGBW Controller 2 has 0-10V inputs. There is no 0-10V output. Output is controlled by PWM at 244Hz,
We recommend using momentary switches for comfortable light control.

 

Notes for diagrams:

P – 12/24V DC power supply connector

GND – ground connector

IN1 – input connector for controlling OUT1 output

IN2 – input connector for controlling OUT2 output

IN3 – input connector for controlling OUT3 output

IN4 – input connector for controlling OUT4 output

OUT1 – output connector controlled by IN1 input (red LED color recommended)

OUT2 – output connector controlled by IN2 input (green LED color recommended)

OUT3 – output connector controlled by IN3 input (blue LED color recommended)

OUT4 – output connector controlled by IN4 input (white LED color recommended)

B – service button (used to add/remove the device)

 

 Connection with RGBW/RGB LED strip

We recommend connecting LED strip channels in the same order as on the diagram (R – OUT1, G – OUT2, B – OUT3, W – OUT4).

If you want to connect RGB strip, use the same diagram, but do not connect OUT4 channel.

  1. Disconnect the power.
  2. Connect with the diagram below:

     

    Diagram 1: Example connection with RGBW LED strip
    (1 – power supply, 2 – switch, 3 – RGBW LED strip)

  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.

    The device works in RGBW mode by default, to enable HSB mode change parameter 150 to 1.

 

 Connection with one-color LED strips

  1. Disconnect the power.
  2. Connect with the diagram below:

     

    Diagram 3: Example connection with 4 one-color LED strips
    (1 – power supply, 2 – switch, 4 – one-color LED strip)

  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.

 

 Connection with halogen lights

  1. Disconnect the power.
  2. Connect with the diagram below:

     

    Diagram 4: Example connection with 4 halogen lights
    (1 – power supply, 2 – switch, 5 – halogen light)

  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.

 

 Connection with 0-10V analog sensors

The 2-wire analog sensor requires pull-up resistor.
You can connect up to 4 analog sensors to IN1/IN2/IN3/IN4 terminals.

  1. Disconnect power.
  2. Connect with the diagram below:

    Diagram 5: Example connection with 4 0-10V analog sensors
    (1 – power supply, 6 – 3-wire 0-10V analog sensor, 7 – 2-wire 0-10V analog sensor, 8 – configurable pull-up resistors)
  3. Verify correctness of connection.
  4. Power the device.
  5. Add the device to the Z-Wave network.
  6. Change values of parameters:
    • Connected to IN1:
      • Does not require pull-up: change parameter 20 to 0
      • Requires pull-up: change parameter 20 to 1
    • Connected to IN2:
      • Does not require pull-up: change parameter 21 to 0
      • Requires pull-up: change parameter 21 to 1
    • Connected to IN3:
      • Does not require pull-up: change parameter 22 to 0
      • Requires pull-up: change parameter 22 to 1
    • Connected to IN4:
      • Does not require pull-up: change parameter 23 to 0
      • Requires pull-up: change parameter 23 to 1

 

Z-Wave network

 Adding to the network

Adding (Inclusion) – Z-Wave device learning mode, allowing to add the device to existing Z-Wave network.

Full DSK code is present only on the box, make sure to keep it or copy the code.

To add the device to the Z-Wave network manually:

  1. Power the device.
  2. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
  3. Quickly, three times click the button.
  4. If you are adding in Security S2 Authenticated, input the underlined part of the DSK (label on the box).
  5. LED will start blinking yellow, wait for the adding process to end.
  6. Adding result will be confirmed by the Z-Wave controller’s message and the LED:
    • Green – successful (non-secure, S0, S2 Unauthenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.

 

SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. SmartStart product will be added automatically within 10 minutes of being switched on in the network range.

To add the device to the Z-Wave network using Smart Start:

  1. To use SmartStart your controller needs to support Security S2 (see the controller’s manual).
  2. Enter the full DSK string code to your controller. If your controller is capable of QR scanning, scan the QR code placed on the label on the box.
  3. Power the device.
  4. Wait for the adding process to start (up to few minutes), which is signalled with yellow LED blinking.
  5. Adding result will be confirmed by the Z-Wave controller’s message and the LED:
    • Green – successful (non-secure, S0, S2 Unauthenticated),
    • Magenta – successful (Security S2 Authenticated),
    • Red – not successful.

      In case of problems with adding the device, please reset the device and repeat the adding procedure.

 

 Removing from the network

Removing (Exclusion) – Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. Removing also results in resetting the device to factory defaults.

To remove the device from the Z-Wave network:

  1. Power the device.
  2. Set the main controller into remove mode (see the controller’s manual).
  3. Quickly, three times click the service button.
  4. LED will start blinking yellow, wait for the removing process to end.
  5. Successful removing will be confirmed by the Z-Wave controller’s message and red LED colour.

 

Operating the device

 Operating the device using switches

Controlling connected loads in RGBW mode (default)

Input can control output only with the same number (e.g. switch connected to IN1 controls load connected to output OUT1). Perform following actions on inputs to change state of the connected load:

    • 1xclick – change to the opposite one (ON/OFF)

A single click switches between the OFF state and the last non-OFF state. It means it may set the colour back, but the light may not light up as it doesn’t change the brigthness.

  • 2xclick – set colour to 100%
  • hold/release – dimm/brighten colour

 


Controlling connected loads in HSB mode

 

HSB mode is enabled by setting parameter 150 to 1. Inputs correspond to different components in HSB colour space: IN1 – Hue, IN2 – Saturation, IN3 – Brightness and IN4 input controls OUT4 output. Perform following actions on inputs to change values of the components:

  • 1xclick when value is 0 – restore last set value
  • 1xclick when value is not 0 – set value to 0
  • 2xclick – set value to max
  • hold/release – increase/decrease value

When you hold the button connected to IN1, you revolve around the cone on the H (Hue) axis.
When you hold the button connected to IN2, you change the saturation (S).
When you hold the button connected to the IN3, you change the brightness (B).

 

Remember that if the saturation is too low, you may not notice any changes while holding IN1.

 

Other actions

1,2,3xclick/hold/release – activate scene in the controller for specific action (requires prior configuration)

 

 Visual indications

The built-in LED light shows current device status.

After powering the device:

  • Green – device added to a Z-Wave network (without Security S2 Authenticated)
  • Magenta – device added to a Z-Wave network (with Security S2 Authenticated)
  • Red – device not added to a Z-Wave network

Update:

  • Blinking cyan – update in progress
  • Green – update successful
  • Red – update not successful

Menu:

  • Blinking green – entering the menu (added without Security S2 Authenticated)
  • Blinking magenta – entering the menu (added with Security S2 Authenticated)
  • Blinking red – entering the menu (not added to a Z-Wave network)
  • Green – reset energy consumption memory
  • Yellow – reset to factory defaults

 

 Menu

Menu allows to perform Z-Wave network actions. In order to use the menu:

  1. Press and hold the service button to enter the menu, device blinks to signal adding status (see: Visual indications).
  2. Release the service button when device signals desired position with colour:
    • GREEN – reset energy consumption memory
    • YELLOW – reset to factory defaults
  3. Quickly click the service button to select, 2 blinks of the same colour will confirm the selection.

 

 Resetting to factory defaults

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted. Resetting to factory defaults does not reset energy consumption memory.

Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.

  1. Press and hold the service button to enter the menu.
  2. Release service button when the device glows yellow.
  3. Quickly click the service button to confirm.
  4. After few seconds the device will be restarted, which is signalled with the red colour.

 

Additional features

 Activating scenes

The device can activate scenes in the Z-Wave controller by sending scene ID and attribute of a specific action using Central Scene Command Class.

In order for this functionality to work, connect momentary or toggle switch to the IN1-IN4 inputs and set parameters 20-23 to 2, 3 or 4 (depending on type of switch). By default scenes are not activated, set parameters 40-43 to enable scene activation for selected inputs and actions.

Scene IDs for inputs

Input

Scene ID

IN1

1

IN2

2

IN3

3

IN4

4

 

Attributes for actions

Action

Attribute

Switch clicked once

Key Pressed 1 time

Switch clicked twice

Key Pressed 2 times

Switch clicked thrice

Key Pressed 3 times

Switch held*

Key Held Down

Switch released*

Key Released

 

Configuration

 Associations

Association (linking devices) – direct control of other devices within the Z-Wave system network.

Associations allow:

    • reporting the device status to the Z-Wave controller (using Lifeline group),
    • creating simple automations by controlling other devices without participation of the main controller (using groups assigned to actions on the device).

 

Commands send to 2nd–10th association groups reflect inputs operation according to device configuration, e.g. turning the first channel on using input will send frame responsible for the same action.

The device provides the association of 10 groups:

1st association group – “Lifeline” reports the device status and allows for assigning single device only (main controller by default).
2nd association group – “RGBW Sync” allows to synchronize state of other FIBARO RGBW Controller devices (FGRGBW-442 and FGRGBWM-441) – do not use with other devices.
3rd association group – “On/Off (IN1)” is used to turn the associated devices on/off reflecting IN1 operation.
4th association group – “Dimmer (IN1)” is used to change level of associated devices reflecting IN1 operation.
5th association group – “On/Off (IN2)” is used to turn the associated devices on/off reflecting IN2 operation.
6th association group – “Dimmer (IN2)” is used to change level of associated devices reflecting IN2 operation.
7th association group – “On/Off (IN3)” is used to turn the associated devices on/off reflecting IN3 operation.
8th association group – “Dimmer (IN3)” is used to change level of associated devices reflecting IN3 operation.
9th association group – “On/Off (IN4)” is used to turn the associated devices on/off reflecting IN4 operation.
10th association group – “Dimmer (IN4)” is used to change level of associated devices reflecting IN4 operation.

The device allows to control 5 regular or multichannel devices per an association group, with the exception of “LifeLine” that is reserved solely for the controller and hence only 1 node can be assigned.

Association groups 2-10 can be triggered only from buttons connected to IN1-IN4 and will not work for 0-10V sensors.

Producent Fibaro
Dimensioner 42.5 x 38.25 x 20.3 mm
Vægt 0.2000
EU regulations EN55022(radiobølge interferens), EN61000-6 (sikkerheden ved brug)
Radiofrekvens 868 MHz
Radio-protokol: Z-Wave Plus
Elforbrug < 0,8W
Arbejds temperatur 10°C - 40°C
Rækkevidde Udendørs ca 50meter, indendørs op til 30meter

Indsend din bedømmelse

Kun registrerede brugere kan skrive bedømmelser. Log ind eller registrer